Flexible air duct purchase must ask 7 questions: engineers will not tell you screening logic

Why do professional buyers screen suppliers by these 7 questions?

There is a serious information asymmetry in the performance parameters of flexible ducts:

  • Similar products claimed to be “high temperature resistant 120℃”, but deformed at 60℃ in the actual test.
  • “CE marking” may only refer to the compliance of packaging materials, not the duct itself.
  • Confusing fire rating labeling (BS 476? EN 13501? NFPA 260?).

This article provides a questioning system validated by ASTM/ISO test methodology to help you get to the real performance of your product.


Essential Question 1: How is the temperature range verified? Look at the TGA curve or manufacturer's dictation?

Technical Analysis

Key Indicators:

  • Glass transition temperature (Tg): the critical point at which the material starts to soften
  • Temperature of heat loss (Td₅%): the temperature at which 5% of the mass is lost (measured value should be > nominal temperature resistance)

Validation Methods:

  • Require manufacturers to provide TGA (Thermogravimetric Analysis) report, compared to the ASTM E1131 standard curve.
  • Be wary of the “instantaneous temperature resistance” word game, need to clarify the continuous operating temperature range.


Essential Question 2: What international standards do the fire ratings correspond to? How to convert?

Global Mainstream Standards Comparison Table

AreaStandardGrade DefinitionEquivalent conversion formula
European UnionEN 13501-1A2-s1,d0 (highest grade)s1=Smoke density ≤ 50%
North AmericaUL 94 V-0 (self-extinguishing within 2 seconds from fire)Correlation test with UL 723 radiant flux
ChinaGB 8624 B1 (flame retardant) Additional rating for smoke production toxicity

Pit Avoidance Guide: Requirement of SBI (Single-Body-Ignition Test) Reports from Third-Party Laboratories


Essential Question 3: What are the hidden terms behind the certification mark?

In-depth interpretation of the certificate highlights

Global Mainstream Standards Comparison Table

Type of CertificationKey Test ItemsOverlooked qualifications
UL 181Flame spread ≤25Only for pipe diameter ≤254mm
CE CPRContinuous burning ≤150mmEvaluation of joints is not included
FMVSS 302Burning rate ≤100mm/minTested in horizontal position only

Recommendation for action: Require vendors to provide a scanned copy of the “Scope of Application” page of the certification.