loading

Specializing in PVC flexible duct industry Custom manufacturer

NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 1
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 2
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 3
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 4
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 5
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 6
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 7
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 1
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 2
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 3
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 4
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 5
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 6
NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose 7

NUOENWEI Anti-static Blower Ducting | Conductive Flexible Hose

NUOENWEI Anti-static Blower Ducting is specially developed for industrial ventilation systems that require flexible air delivery and static electricity dissipation.

The duct features a flame-retardant PVC-coated fabric body reinforced with high-carbon spring steel wire and abrasion-resistant protective strips. Its conductive construction incorporates two tinned braided copper wires connected to the internal steel wire reinforcement, providing multiple conductive paths for grounding and static charge dissipation.

Designed for convenient installation and transportation, this flexible blower duct can be extended, compressed, and bent to accommodate different working environments. Hanging loops positioned approximately every meter make it easy to secure the duct along ventilation routes.

With customizable diameters from 100 mm to 1500 mm and standard lengths of 5 m or 10 m, NUOENWEI provides flexible ventilation solutions for mining, tunneling, underground construction, shipbuilding, welding, and industrial air supply and exhaust systems.

5.0
Place of Origin:
Guangdong, China
Minimum order quantity:
5 meters
Supply Ability:
Ordinary air duct 500000 meters per year,PCA hose 200000 meters per year
Packing:
Pack according to custom length
Delivery time:
Please check with us before placing order
Transaction mode:
T/T,Western Union, Paypal
ODM & OEM:
Available
Certification:
ISO9001,IEC 62631,AS/NZS 1530
design customization

    oops...!

    no product data.

    Go to homepage

    NUOENWEI Anti-static Blower Ducting – Flexible Conductive Ventilation Hose

    NUOENWEI Anti-static Blower Ducting is engineered for industrial environments where effective ventilation and static charge dissipation are essential. It is designed to work with portable explosion-proof blowers and industrial ventilation equipment, providing a flexible solution for supplying fresh air and exhausting contaminated air.


    Conductive and Anti-static Construction

    The duct body is manufactured from flame-retardant PVC-coated fabric reinforced with high-carbon spring steel wire. Its conductive structure incorporates two tinned braided copper wires installed at both ends of the hose and interconnected with the steel wire reinforcement.

    This multi-path conductive design facilitates electrical continuity and grounding, helping dissipate static charges generated during equipment operation when properly connected to an appropriate grounding system.


    Flexible Design for Industrial Ventilation

    The flexible structure allows the duct to be extended, compressed, and bent according to different installation requirements. It can be easily connected to portable blowers using suitable belts or polypropylene ropes. Multiple duct sections can also be connected to extend the ventilation distance.

    Hanging loops are installed at approximately one-meter intervals, allowing the duct to be secured along walls, ceilings, or other suitable support structures.


    Durable Material for Demanding Environments

    The PVC-coated fabric provides resistance to abrasion, tearing, moisture, acids, and corrosion. Its flame-retardant properties and operating temperature range of -15°C to +80°C make it suitable for various industrial ventilation environments.

    With customizable diameters from 100 mm to 1500 mm, NUOENWEI Anti-static Blower Ducting offers a practical solution for industrial air supply, exhaust ventilation, and applications requiring conductive flexible ducting.

    NUOENWEI Anti-static Blower Ducting
    NUOENWEI Anti-static Blower Ducting-6

    Related Parameters

    Product Specifications
    Product Name Anti-static Blower Ducting
    Brand NUOENWEI
    Product Type Conductive Flexible Ventilation Duct
    Material Flame-retardant PVC-coated fabric
    Reinforcement High-carbon spring steel wire
    Protective Layer Abrasion-resistant strips
    Conductive Structure Conductive duct body with dual tinned braided copper wires
    Conductive Fabric Resistance 2 × 10³ Ω (as specified)
    Fabric Thickness 0.4–0.65 mm
    Inner Diameter 4"–59" (100–1500 mm)
    Standard Length 5 m / 10 m
    Color Black
    Operating Temperature -15°C to +80°C
    Structure Flexible, extendable and compressible
    Hanging System Hanging loops approximately every 1 m
    Connection Belts, PP ropes or suitable duct connectors
    Applications Mining, tunnels, shipyards, welding, underground construction and industrial ventilation
    Customization Diameter, length and material options

    Key Features and Advantages of NUOENWEI Anti-static Blower Ducting

    1. Conductive Structure for Static Charge Dissipation

    The anti-static blower duct features a conductive fabric body and two tinned braided copper wires connected to the steel wire reinforcement. This multi-path conductive construction facilitates grounding and helps dissipate accumulated static electricity during ventilation operations.

    2. Flame-Retardant PVC-Coated Fabric

    Manufactured from B-grade flame-retardant PVC-coated fabric, the duct provides resistance to abrasion, tearing, moisture, acids, and corrosion. It is designed to withstand demanding industrial working conditions.

    3. Flexible, Extendable and Compressible Design

    The high-carbon spring steel wire reinforcement allows the duct to bend, extend, and compress easily. Its flexible construction simplifies installation in confined spaces and around obstacles.

    4. Convenient Hanging and Installation

    Hanging loops are positioned approximately every meter along the duct body, making it easier to secure the ventilation hose in the required position. The duct can be connected to compatible portable blowers using belts or polypropylene ropes.

    5. Multiple Conductive Paths

    The integration of conductive fabric, spring steel wire, and dual tinned braided copper wires provides multiple conductive paths. The copper wires facilitate grounding connections and help improve electrical continuity throughout the duct assembly.

    6. Lightweight and Easy to Transport

    The flexible fabric construction makes the duct convenient to carry, store, and install. Its compressible design helps reduce storage space and simplifies transportation between different job sites.

    7. Customizable Sizes and Lengths

    Available in inner diameters from 100 mm to 1500 mm, with standard lengths of 5 m and 10 m. Custom dimensions and material options can be discussed to meet different industrial ventilation requirements.

    Applications of Anti-static Blower Ducting

    NUOENWEI Anti-static Blower Ducting is suitable for various industrial ventilation applications where flexible air delivery and static charge dissipation are required.

    Mining Ventilation

    Used with compatible mine ventilation blowers to supply fresh air and assist with air circulation in underground mining operations.

    Tunnel Ventilation

    Suitable for tunnel construction and maintenance projects, helping deliver fresh air to enclosed working areas and remove stale air.

    Underground Construction

    Designed for temporary ventilation systems in underground construction sites, basements, and other enclosed working environments.

    Shipyards and Marine Workshops

    Used for air supply and exhaust ventilation in shipbuilding facilities, maintenance areas, and confined workspaces.

    Welding and Industrial Workshops

    Suitable for ventilation applications in welding workshops and manufacturing facilities where localized air supply or exhaust is required.

    Laboratory and Equipment Rooms

    Can be used in compatible ventilation systems for laboratories, machinery rooms, and other industrial facilities requiring flexible air distribution.

    Municipal Pipeline and Fire Ventilation Projects

    Suitable for temporary ventilation in municipal pipeline engineering, maintenance projects, and applicable fire ventilation operations.

    Industrial Exhaust and Fresh Air Supply

    Designed to work with compatible portable blowers for supplying fresh air or exhausting unwanted air from industrial work areas.

    Frequently Asked Questions

    1
    What is anti-static blower ducting used for?
    Anti-static blower ducting is used in industrial ventilation systems where static charge dissipation is important. It helps deliver fresh air or exhaust unwanted air in environments such as mines, tunnels, underground construction sites, shipyards, and industrial workshops.
    2
    How does NUOENWEI anti-static ducting dissipate static electricity?
    The duct features a conductive fabric body, reinforced steel wire, and two tinned braided copper wires. These components provide conductive paths that facilitate grounding and help dissipate accumulated static charges when properly connected to a suitable grounding system.
    3
    What materials are used in this conductive ventilation duct?
    The duct is manufactured from flame-retardant PVC-coated fabric reinforced with high-carbon spring steel wire. Abrasion-resistant protective strips are also incorporated into its construction.
    4
    What diameters are available?
    NUOENWEI Anti-static Blower Ducting is available in inner diameters ranging from 100 mm to 1500 mm (4 inches to 59 inches). Custom sizes can be discussed according to project requirements.
    5
    What are the standard duct lengths?
    The standard lengths are 5 meters and 10 meters. Other lengths can be customized according to specific installation requirements.
    6
    What is the operating temperature range?
    The standard operating temperature range is -15°C to +80°C. Special cold-resistant or high-temperature material options may be available upon request.
    7
    Can the duct be connected to an explosion-proof blower?
    Yes. The duct is designed for connection to compatible portable explosion-proof blowers and industrial ventilation equipment. Appropriate connectors, grounding arrangements, and equipment compatibility should be confirmed before installation.
    8
    Is the anti-static blower duct flexible and easy to install?
    Yes. Its spring steel wire reinforcement allows the duct to bend, extend, and compress. Hanging loops installed at approximately one-meter intervals also make installation and positioning more convenient.
    9
    Can multiple duct sections be connected together?
    Yes. Multiple sections can be connected using suitable connection methods to extend the ventilation route. The connection should maintain the required airflow performance and electrical continuity where grounding is necessary.
    10
    Does NUOENWEI offer customized anti-static ventilation ducts?
    Yes. NUOENWEI can discuss customized diameters, lengths, and material options according to different industrial ventilation requirements. Contact our team with your project specifications for further assistance.
    leave a message
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    Copyright © 2026 Foshan nuoenwei.com | Sitemap   |  Privacy Policy

    Customer service